LUNA 108 AL. Công tắc cảm ứng ánh sáng, 2~100lx, trễ bật/tắt: 20/80s

  • Liên hệ
  • The LUNA 108 is an electronic switch, consisting of a DIN-type main module and a removable light sensor, which automatically switches on (load) at night and shuts off at daylight. Brightness thresholds can be adjusted from 5 to 100 lux. The delay time is 20 seconds, off is 80 seconds (no change). LUNA 108 has one control channel, normally open contact (N.O.), 16A / 230VAC load The LUNA 108 AL has an integrated floating sensor (IP54) and a LUNA 108 EL with an immersive light sensor (IP65). ■ Analogue twilight switch ■ External light sensor included in delivery ■ Fixed On and Off switching delay ■ to avoid faulty operation caused by lightning, car headlights etc. ■ Display of channel and switching status ■ Infinitely adjustable switching brightness
LUNA108 controls turn on and off the lighting system (load) according to ambient light intensity. The LUNA 108 consists of a main unit designed to be mounted on a DIN rail, which has a compact size (17.5mm wide = 1 module), and a removable dual sensor (AL).
The main applications are controlling public lighting systems, workshops, garden lights, billboards, tree planting, animal husbandry, etc.
In high latitude areas such as the North of Vietnam, where dark and light days vary widely between summer and winter and depending on the weather and terrain, the light sensor switches are much more advantageous. compared to the time switch because it can be switched on / off accurately according to actual lighting conditions.
Main features include:
  • Touch-sensitive lighting technology.
  • Designed for DIN rail mounting.
  • Compact size with one horizontal module (17.5mm).
  • Removable sensor, cable distance between sensor and main module 25m.
  • 2 different versions with wall mounted sensor / column (AL) or immersion mount (EL).
  • Adjustable brightness on / off level, 2 ~ 100 lux.
  • Delayed turn on = 20s and off delay = 80s to avoid malfunction due to flashing, auto phase or cloud passing.
  • Indicates active and closed status LEDs (red and green).
  • Screw-type connector.

 

LUNA_108_AL

Operating voltage                                     220 – 240 V AC


Frequency                                                   50 – 60 Hz


Number of channels                                       1


Stand-by consumption                                ~0,8 W


Capacity loss max .                                           0,9 W


Setting range brightness                             2 – 100 lx


Switch-on delay                                                20 s


Switch-off delay                                               80 s


Type of contact                                             NO contact


Switching output                                          Potential-free


Width                                                               1 modules


Installation type                                              DIN rail


Type of connection                                         Screw terminals


Switching capacity                       16 A (at 250 V AC, cos φ = 1), 10 AX (Fluorescent lamp load)


Incandescent lamp load                                       2300 W


Halogen lamp load                                                2300 W


Fluorescent lamp load (conventional) not corrected                                        2300 VA


Fluorescent lamp load (conventional) series-corrected                                  2300 VA


Fluorescent lamp load (conventional) lead-lag circuit                                      2300 VA


Fluorescent lamp load (conventional) parallel-corrected                              400 VA 42 μF


LED lamp < 2 W                                                                                           20 W


LED lamp 2-8 W                                                                                           55 W


LED lamp > 8 W                                                                                           70 W


Energy saving lamps                                                                                   90 W


Fluorescent lamp load (electronic ballast)                                                300 W


Test approval                                                                                               VDE


Lichtsensor                                                                                      Surface-mounted light sensor


Housing and insulation material                       High-temperature resistant, self-extinguishing thermoplastic


Ambient temperature                                                                           -25 °C ... +50 °C


Type of protection                                                                            IP 20, sensor IP 54


Protection class                                                                                             II


Max. cable length to sensor                                                                      25 m